OPERATOR’S MANUAL
INCLUDING:ĂSERVICE KITS, GENERAL DESCRIPTION & TROUBLESHOOTING
 BASIC PUMP
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
3” AIR MOTOR
50:1 RATIO
2 1/4” STROKE
ALSOINCLUDE MANUALS: 6641X-X AIR MOTOR MANUAL, FORM 3637-2GENERALINĆ
FORMATION SHEET.
66650
35 LB DRUM
66650
RELEASED: 6–23–95
(REV. A) IPP/PSE
SERVICE KITS
Use only genuine AROR replacement parts to assure compatible
pressure rating and longest service life.
637066-B for repair of Air Motor section.
Order individual parts for repair of Lower Pump section.
GENERAL DESCRIPTION
This model is designed for delivery of heavy viscosity fluids such as
chassis lubrication fluids. Material dispensing accessories and supply
lines and fittings must be capable of withstanding pressures developed
by pump.
The ARO 50:1 ratio basic pump assembly consists of a 3" air motor
and lower pump end.
RATIO x REGULATED AIR PRESSURE TO AIR MOTOR = MAXIMUM FLUID
PRESSURE.
The 50:1 ratio is an expression of the relationship between the air
motor area and the lower pump end area. When 150 p.s.i. (10 bar)
air pressure is supplied to the air motor, the lower pump end will
develop a maximum of 7,500 p.s.i. (517 bar) fluid pressure (at no
flow) - as the fluid control is opened, the flow rate will increase as
the air motor cycle rate increases to keep up with the demand.
PUMP DATA
Air Motor
FIGURE 1
66410
1/2 NPT
Mat’l Outlet
Mat’l Inlet
Lower Pump
28.5"
20.2"
(723.9 mm)
(513.3 mm)
F031
OPERATING AND SAFETY PRECAUTIONS
HEED ALL WARNINGS.
DONOT EXCEED MAXIMUM WORKING PRESSURE OF 7,500 PSI (517
BAR) AT 150 PSI (10 BAR) AIR INLET PRESSURE.
 WARNING
: HIGH PRESSURE DEVICE. Improper usage of
this equipment could result in serious injury. The possibility
of injection into the flesh is a potential hazard. Never allow any
part of the human body to come in front of or in direct contact
with the material outlet. An injection injury can be serious. If
injection should occur, contact a qualified physician immediĆ
ately for treatment.
COMPONENTRUPTURE.Thispumpiscapableofproducinghighmaterial
pressure as stated on pump model plate.
Be sure material hoses and other components are able to withstand fluid
pressures developed by this pump.
Donotoperatepumpcontinuouslyatspeedsinexcessof75cyclesperminĆ
ute.
 WARNING
: PREVENT STATIC SPARKING. If static sparking
occurs, fire or explosion could result. Pump, dispensing
valve and containers must be grounded when handling inĆ
flammable fluids such as petroleum products, paints, lacĆ
quers, etc. and wherever discharge of static electricity is a
hazard.
Usegrounded hoses (static wire) and be sure the object is grounded if it can
produce a static charge.
Use grounded hoses (static wire) and be sure the object is
grounded if it can produce a static charge.
Disconnectair line from pump air motor when system sits idle for long periĆ
ods of time.
THE ARO CORPORATION 
D
 ONE ARO CENTER 
D
 BRYAN, OHIO 43506–0151
E
1995 THE ARO CORPORATION 
D
 PRINTED IN U.S.A.
&
 (419) 636–4242 
D