4 -  12 
4. OPERATION 
 
4.2.4 Absolute value command/incremental value command specifying system 
This system is an auxiliary function for point tables to use them by specifying the absolute value 
command and incremental value command. 
(1) Point table 
Set each value of point tables by using MR Configurator (Setup software) or operation section. 
Set to point tables the following, "Position data", "Servo motor speed", "Acceleration time constant", 
"Deceleration time constant", "Dwell time" and "Auxiliary function". 
To specify the command system, set "Auxiliary function" as shown below. 
  For absolute value command system, set "0" or "1". 
  For incremental value command system, set "2" or "3". 
Name Setting 
range Unit 
Description 
Position data 
999999 to 999999 
10
STM
(1) When this point table is used in an absolute value command system 
Set the target address (absolute value). 
This value can also be set using the teaching function. (Refer to section 
7.10.) 
(2) When this point table is used in an incremental value command system 
Set the moving distance. A " " sign indicates a reverse rotation 
command. 
The teaching function is unusable. 
Servo motor 
speed 
0 to permissible speed 
r/min 
Set the command speed of the servo motor for execution of positioning. 
The setting should be equal to or less than the instantaneous permissible 
speed of the servo motor. 
Acceleration 
time constant 
0 to 20000 
ms 
Set the acceleration time constant. 
Set the time until the rated speed of the servo motor is reached. 
Deceleration 
time constant 
0 to 20000 
ms 
Set the deceleration time constant. 
Set the time until the servo motor running at rated speed comes to a stop. 
Dwell 
0 to 20000 
ms 
Set the dwell. 
Set "0" or "2" in the auxiliary function to make the dwell invalid. 
Set "1" or "3" in the auxiliary function and 0 in the dwell to perform 
continuous operation. 
When the dwell is set, the position command of the selected point table is 
completed, and after the set dwell has elapsed, the position command of the 
next point table is started. 
Auxiliary 
function 
0 to 3 
 
Set the auxiliary function. 
(1) When this point table is used in an absolute value command system 
0: Automatic operation is performed in accordance with a single point table 
chosen. 
1: Operation is performed in accordance with consecutive point tables 
without a stop. 
 
(2) When this point table is used in an incremental value command system 
2: Automatic operation is performed in accordance with a single point table 
chosen. 
3: Operation is performed in accordance with consecutive point tables 
without a stop. 
When a different rotation direction is set, smoothing zero (command 
output) is confirmed and the rotation direction is then reversed. 
Setting "1" or "3" in point table No.31 results in an error. 
For full information, refer to section 4.2.6.