4 -  15 
4. OPERATION 
 
4.2.6 Automatic continuous operation 
(1) What is automatic continuous operation? 
By merely choosing one point table and making a start (ST1 or ST2), operation can be performed in 
accordance with the point tables having consecutive numbers. 
Automatic operation is available in two types: varied speed operation and automatic continuous 
positioning operation. 
Either type may be selected as follows. 
(a) In absolute value command system or incremental value command system 
Point table setting 
Dwell Auxiliary 
function 
0 1 
Automatic continuous 
operation
Speed changing operation
Automatic continuous 
positioning operation
 
1 or more 
 
(b) In absolute value command /incremental value command specifying system 
 
Point table setting 
 
Auxiliary function 
Dwell 
When position data is 
absolute value 
When position data is 
incremental value 
0 1 
Automatic continuous 
operation
Speed changing operation
Automatic continuous 
positioning operation
 
1 or more 
 
(2) Varied speed operation 
Speed during positioning operation can be changed by setting the auxiliary function of the point table. 
Use the number of point tables equal to the number of speeds to be set. 
By setting "1" to the auxiliary function, operation is performed at the speed set in the next point table 
during positioning. The position data valid at this time is the data selected at start and the 
acceleration and deceleration time constants of the subsequent point tables are made invalid. 
By setting "1" to the auxiliary function of up to point table No.30, operation can be performed at a 
maximum of 31 speeds. Set "0" to the auxiliary function of the last point table. 
When performing varied speed operation, always set "0" to the dwell. If "1" or more is set, automatic 
continuous positioning operation is made valid. 
The following table gives a setting example. 
Point table No. 
Dwell [ms] (Note 1) 
Auxiliary function 
Variable speed operation 
1 0 1 
2 0 1 
3 0 
(Note 2)
 
Consecutive point table data 
4 0 1 
5 0 1 
6 0 1 
7 0 
(Note 2)
 
Consecutive point table data 
Note 1. Always set "0". 