Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
4 -  26 
4. OPERATION 
 
4.4 Manual home position return mode 
4.4.1 Outline of home position return 
Home position return is performed to match the command coordinates with the machine coordinates. In 
the incremental system, home position return is required every time input power is switched on. In the 
absolute position detection system, once home position return is done at the time of installation, the 
current position is retained if power is switched off. Hence, home position return is not required when 
power is switched on again. 
This servo amplifier has the home position return methods given in this section. Choose the most 
appropriate method for your machine structure and application. 
This servo amplifier has the home position return automatic return function which executes home 
position return by making an automatic return to a proper position if the machine has stopped beyond or 
at the proximity dog. Manual motion by jog operation or the like is not required. 
 
(1) Manual home position return types 
Choose the optimum home position return according to the machine type, etc. 
Type 
Home position return method 
Features 
Dog type home position 
return 
With deceleration started at the front end of a 
proximity dog, the position where the first 
Z-phase signal is given past the rear end of the dog or 
a motion has been made over the home position shift 
distance starting from the Z-phase signal is defined as 
a home position.(Note) 
General home position return method using a 
proximity dog. 
Repeatability of home position return is 
excellent. 
The machine is less burdened. 
Used when the width of the proximity dog can 
be set greater than the deceleration distance 
of the servo motor. 
Count type home position 
return 
With deceleration started at the front end of a 
proximity dog, the position where the first Z-phase 
signal is given after advancement over the preset 
moving distance after the proximity dog or a motion 
has been made over the home position shift distance 
starting from the Z-phase signal is defined as a home 
position. 
Home position return method using a 
proximity dog. 
Used when it is desired to minimize the length 
of the proximity dog. 
Data setting type home 
position return 
The position reached after any automatic motion is 
defined as a home position. 
No proximity dog required. 
Stopper type home 
position return 
The position where the machine stops when its part is 
pressed against a machine stopper is defined as a 
home position. 
Since the machine part collides with the 
machine be fully lowered. 
The machine and stopper strength must be 
increased. 
Home position ignorance 
(Servo-on position as 
home position) 
The position where servo is switched on is defined as 
a home position. 
 
Dog type rear end 
reference 
The position where the axis, which had started 
decelerating at the front end of a proximity dog, has 
moved the after-proximity dog moving distance and 
home position shift distance after it passed the rear 
end is defined as a home position. 
The Z-phase signal is not needed. 
Count type front end 
reference 
The position where the axis, which had started 
decelerating at the front end of a proximity dog, has 
moved the after-proximity dog moving distance and 
home position shift distance is defined as a home 
position. 
The Z-phase signal is not needed. 
Dog cradle type 
The position where the first Z-phase signal is issued 
after detection of the proximity dog front end is 
defined as a home position. 
 
Note. The Z-phase signal is a signal recognized in the servo amplifier once per servo motor revolution and cannot be used as an output 
signal.