4.5 Absolute position detection system 
CAUTION 
If an absolute position erase alarm (AL.25) or an absolute position counter warning 
(AL.E3) has occurred, always perform home position setting again. Not doing so 
can cause runaway. 
 
POINT 
 
When the following parameters are changed, the home position is lost 
when turning on the power after the change. Execute the home position 
return again when turning on the power. 
First digit of parameter No.1 (ST1 coordinate system selection) 
Parameter No. 4 (Electronic gear numerator) 
Parameter No. 5 (Electronic gear denominator) 
Parameter No. 42 (Home position return position data) 
 
This servo amplifier contains a single-axis controller. Also, all servo motor encoders are compatible with 
an absolute position system. Hence, an absolute position detection system can be configured up by merely 
loading an absolute position data back-up battery and setting parameter values. 
 
(1) Restrictions 
An absolute position detection system cannot be built under the following conditions. 
 
1) Stroke-less coordinate system, e.g. rotary shaft, infinite positioning. 
 
2) Operation performed in incremental value command type positioning system. 
 
(2) Specifications 
 
Item Description 
System 
Electronic battery backup system 
Battery 
1 piece of lithium battery ( primary battery, nominal   3.6V) 
Type: MR-BAT or A6BAT 
Maximum revolution range 
Home position   32767 rev. 
(Note 1)
 Maximum speed at power failure 
500r/min 
(Note 2)
 Battery backup time 
Approx. 10,000 hours (battery life with power off) 
(Note 3)
 Data holding time during battery 
replacement 
2 hours at delivery, 1 hour in 5 years after delivery 
Battery storage period 
5 years from date of manufacture 
Note 1. Maximum speed available when the shaft is rotated by external force at the time of power failure or the like. 
2. Time to hold data by a battery with power off. It is recommended to replace the battery in three years independently of 
whether power is kept on or off. 
3. Period during which data can be held by the super capacitor in the encoder after power-off, with the battery voltage low or 
the battery removed, or during which data can be held with the encoder cable disconnected. 