Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
7 -  4 
7. DISPLAY AND OPERATION 
 
7.2.3 Status display list 
The following table lists the servo statuses that may be shown. 
Display range 
Status display  Symbol 
Unit 
Description 
Servo amplifier 
display 
MR-DP60 
Current 
position 
PoS 
10
STM
 
mm 
The current position from the machine home position of 0 is 
displayed. 
99999 to 
99999 
999999 to 
999999 
Command 
position 
CPoS 
10
STM
 
mm 
The command position is displayed. 
99999 to 
99999 
999999 to 
999999 
Command 
remaining 
distance 
rn 
10
STM
 
mm 
The command remaining distance of the currently selected 
point table is displayed. 
99999 to 
99999 
999999 to 
999999 
Point table No. 
PT 
 
The point table No. being executed is displayed. 
0 to 31 
0 to 31 
Cumulative 
feedback 
pulses 
C pulse 
Feedback pulses from the servo motor encoder are counted 
and displayed. 
When the value exceeds  9999999, it returns to zero. 
Press the "SET" button to reset the display value to zero. 
99999 to 
99999 
999999 to 
999999 
Servo motor 
speed 
r r/min 
The servo motor speed is displayed. 
" " is added to the speed of the servo motor rotating in the 
CW rotation. 
5400 to 
5400 
5400 to 
5400 
Droop pulses 
pulse 
The number of droop pulses in the deviation counter is 
displayed. 
" " is added to the droop pulses in the CW rotation. 
The displayed number of pulses is not yet multiplied by the 
electronic gear value. 
99999 to 
99999 
999999 to 
999999 
Override F 
The override setting is displayed. 
100% is displayed when override is invalid. 
0 to 200 
0 to 200 
Analog torque 
limit voltage 
u V 
The voltage of the Analog torque limit (TLA) is displayed. 
0.00 to 10.00  0.00 to 10.00 
Regenerative 
load ratio 
L % 
The ratio of regenerative power to permissible regenerative 
power is displayed in %. 
0 to 100 
0 to 100 
Effective load 
ratio 
J % 
The continuous effective load torque is displayed. 
The effective value in the past 15 seconds is displayed 
relative to the rated torque of 100%. 
0 to 300 
0 to 300 
Peak load ratio 
The maximum torque generated during 
acceleration/deceleration, etc. 
The highest value in the past 15 seconds is displayed 
relative to the rated torque of 100%. 
0 to 300 
0 to 300 
Instantaneous 
torque 
T % 
Torque that occurred instantaneously is displayed. 
The value of the torque that occurred is displayed in real 
time relative to the rate torque of 100%. 
0 to 400 
0 to 400 
Within one-
revolution 
position low 
Cy1 pulse 
Position within one revolution is displayed in encoder 
pulses. 
The value returns to 0 when it exceeds the maximum 
number of pulses. 
The value is incremented in the CCW direction of rotation. 
0 to 99999 
Within one-
revolution 
position high 
Cy2 
100 
pulse 
The within one-revolution position is displayed in 100 pulse 
increments of the encoder. 
The value returns to 0 when it exceeds the maximum 
number of pulses. 
The value is incremented in the CCW direction of rotation. 
0 to 1310 
(Note) 
0 to 131071 
ABS counter 
LS 
rev 
Travel value from the home position in the absolute position 
detection systems is displayed in terms of the absolute 
position detectors counter value. 
32768 to 
32767 
32768 to 
32767 
Load inertia 
moment ratio 
dC times 
The estimated ratio of the load inertia moment to the servo 
motor shaft inertia moment is displayed. 
0.0 to 300.0 
0.0 to 300.0 
Bus voltage 
Pn 
The voltage (across P-N) of the main circuit converter is 
displayed. 
0 to 450 
0 to 450 
Note. The MR-DP60 can display the status without dividing it into the high and low orders. The unit is [pulse].