8. GENERAL GAIN ADJUSTMENT 
 
8.3 Manual mode 1 (simple manual adjustment) 
If you are not satisfied with the adjustment of auto tuning, you can make simple manual adjustment with 
three parameters. 
 
8.3.1 Operation of manual mode 1 
In this mode, setting the three gains of position control gain 1 (PG1), speed control gain 2 (VG2) and 
speed integral compensation (VIC) automatically sets the other gains to the optimum values according to 
these gains. 
PG1
VG2
VIC
PG2
VG1
GD2
Automatic setting
User setting
 
Therefore, you can adjust the model adaptive control system in the same image as the general PI control 
system (position gain, speed gain, speed integral time constant). Here, the position gain corresponds to 
PG1, the speed gain to VG2 and the speed integral time constant to VIC. When making gain adjustment 
in this mode, set the load inertia moment ratio (parameter No. 34) correctly. 
 
8.3.2 Adjustment by manual mode 1 
POINT 
 
If machine resonance occurs, adaptive vibration suppression control 
(parameter No. 63) or machine resonance suppression filter (parameter No. 
61 62) may be used to suppress machine resonance. (Refer to section 9.2, 
9.3.) 
 
(1) For speed control 
(a) Parameters 
The following parameters are used for gain adjustment. 
Parameter No. 
Abbreviation 
Name 
PG1 
Position control gain 1 
34 
GD2 
Ratio of load inertia moment to servo motor inertia moment 
37 
VG2 
Speed control gain 2 
38 
VIC 
Speed integral compensation 
 
(b) Adjustment procedure 
Step Operation 
Description 
Set an estimated value to the ratio of load inertia moment to servo motor 
inertia moment (parameter No. 34). 
 
Increase the speed control gain 2 (parameter No. 37) within the vibration- 
and unusual noise-free range, and return slightly if vibration takes place. 
Increase the speed control gain. 
Decrease the speed integral compensation (parameter No. 38) within the 
vibration-free range, and return slightly if vibration takes place. 
Decrease the time constant of the speed 
integral compensation. 
If the gains cannot be increased due to mechanical system resonance or 
the like and the desired response cannot be achieved, response may be 
increased by suppressing resonance with adaptive vibration suppression 
control or machine resonance suppression filter and then executing steps 
2 and 3. 
Suppression of machine resonance. 
Refer to section 9.2, 9.3. 
While checking the settling characteristic and rotational status, fine-
adjust each gain. 
Fine adjustment