11 -  10 
11. TROUBLESHOOTING 
 
Display Name 
Definition 
Cause 
Action 
1. Software limit was set within actual 
operation range. 
Set parameter No. 48 to 51 
correctly. 
2. Point table of position data in excess of 
software limit was executed. 
Set point table correctly. 
AL.98 Software 
limit 
warning 
Software limit set in 
parameter is reached. 
3. Software limit was reached during JOG 
operation or manual pulse generator 
operation. 
Perform operation within 
software limit range. 
AL.9F  Battery warning  Voltage of battery for 
absolute position 
detection system reduced. 
Battery voltage fell to 3.2V or less. 
(Detected with the servo amplifier) 
Change the battery. 
AL.E0 Excessive 
regenerative 
warning 
There is a possibility that 
regenerative power may 
exceed permissible 
regenerative power of 
built-in regenerative 
resistor or regenerative 
option. 
Regenerative power increased to 85% or 
more of permissible regenerative power of 
built-in regenerative resistor or 
regenerative option. 
Checking method
Call the status display and check
regenerative load ratio.
 
1. Reduce frequency of 
positioning. 
2. Change regenerative option 
for the one with larger 
capacity. 
3. Reduce load. 
AL.E1 Overload 
warning 
There is a possibility that 
overload alarm 1 or 2 
may occur. 
Load increased to 85% or more of overload 
alarm 1 or 2 occurrence level. 
Cause, checking method
Refer to AL.50,51.
 
Refer to AL.50, AL.51. 
1. Noise entered the encoder. 
Take noise suppression 
measures. 
Absolute position encoder 
pulses faulty. 
 
2. Encoder faulty. 
Change servo motor. 
AL.E3  Absolute position 
counter warning 
The multi-revolution counter 
value of the absolute position 
encoder exceeded the 
maximum revolution range. 
3. The movement amount from the home 
position exceeded a 32767 rotation or 
37268 rotation in succession. 
Make home position setting 
again. 
AL.E6 Servo forced stop 
warning 
EMG-SG are open. 
External forced stop was made valid. 
(EMG-SG opened.) 
Ensure safety and deactivate 
forced stop. 
AL.E9 Main circuit off 
warning 
Servo was switched on 
with main circuit power 
off. 
 
Switch on main circuit power. 
 
11.3 MR-DP60 external digital display error 
When MR-DP60 external digital display detects an error, the following alarms are displayed. The alarms 
are displayed only on the MR-DP60, but not on the servo amplifier display. 
 
Display Name 
Definition 
Cause 
Action 
AL. CPU  CPU error 
CPU error 
Faulty parts in the MR-D60. 
Exchange the MR-D60. 
AL. C0 
1. CN3 connector disconnected. 
Connect correctly. 
 
Communication 
error 
Communication error  
occurred between MR-DP60 
and MR-J2S-CP. 
2. Wire breakage of the cable. 
Repair or exchange the cable.