Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
2 -  2 
2. INSTALLATION 
 
2.2 Installation direction and clearances  
 CAUTION 
Do not hold the front cover to transport the servo amplifier. The servo amplifier 
may drop. 
The equipment must be installed in the specified direction. Otherwise, a fault may 
occur. 
Leave specified clearances between the servo amplifier and control box inside 
walls or other equipment. 
 
(1) Installation of one servo amplifier  
Control box
Control box
10mm  
(0.4 in.)  
or more
10mm  
(0.4 in.)  
or more
40mm  
(1.6 in.)  
or more
40mm  
(1.6 in.)  
or more
Wiring clearance 
70mm 
(2.8 in.)
Servo amplifier
Up
Down