3. SIGNALS AND WIRING 
 
3.10 Grounding 
WARNING 
Ground the servo amplifier and servo motor securely. 
To prevent an electric shock, always connect the protective earth (PE) terminal of 
the servo amplifier with the protective earth (PE) of the control box. 
 
The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending on 
the wiring and ground cable routing, the servo amplifier may be affected by the switching noise (due to 
di/dt and dv/dt) of the transistor. To prevent such a fault, refer to the following diagram and always 
ground. 
To conform to the EMC Directive, refer to the EMC Installation Guidelines (IB (NA) 67310). 
Control box
Servo amplifier
L
1
L
2
L
3
L
11
L
21
CN1A CN1B
Li
ne
 fi
lter
NFB
MC
Protective earth(PE)
CN2
U
V
W
Outer
box
Servo motor
Ensure to connect it to PE 
terminal of the servo amplifier.
Do not connect it directly to 
the protective earth of 
the control panel.
Encoder
M
U
V
W
(Note)
Power supply
P
ro
g
ra
mma
bl
e
cont
ro
ller
 
Note. For 1-phase 230VAC, connect the power supply to L
1
L
2
 and leave L
3
 open. 
There is no L
3
 for 1-phase 100 to 120VAC power supply. Refer to section 1.2 for the power supply specification.