Maintenance Object Repair Procedures
9-427
CO-TRK (Analog CO Trunk)
9
CO-TRK (Analog CO Trunk)
If ATMS testing is enabled, check the error log for ATMS errors 3840 and 3841. If
the error log indicates that measurements exceeded acceptable thresholds, and
no other trouble is found with test trunk, run the ATMS test call with test
analog-testcall port UUCSSpp full.
the error log indicates that measurements exceeded acceptable thresholds, and
no other trouble is found with test trunk, run the ATMS test call with test
analog-testcall port UUCSSpp full.
NOTE:
Many trunk problems are caused by incorrect settings of parameters on the
trunk group administration form. Settings must be compatible with the local
environment and with parameter settings on the far-end. Refer to
trunk group administration form. Settings must be compatible with the local
environment and with parameter settings on the far-end. Refer to
DEFINITY
Enterprise Communications Server Release 5.4 Administration and Feature
Description. The Application Notes section of that book shows the correct
settings for administrable timers and other parameters on a country-by-
country basis.
Description. The Application Notes section of that book shows the correct
settings for administrable timers and other parameters on a country-by-
country basis.
Analog CO trunks are 2-wire analog lines to the CO which support both incoming
and outgoing calls. CO trunk circuit packs have eight ports, each of which
provides an interface between the 2-wire CO line and the 4-wire TDM bus. The
system supports the following CO trunk circuit packs:
and outgoing calls. CO trunk circuit packs have eight ports, each of which
provides an interface between the 2-wire CO line and the 4-wire TDM bus. The
system supports the following CO trunk circuit packs:
The following sequences show the interactions between the switch and the CO
during call setup for both loop-start and ground-start trunks.
during call setup for both loop-start and ground-start trunks.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
CO-TRK
MAJOR
2
2.
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded
by the set options command and that at least 75% of the trunks in this trunk group
are alarmed.
by the set options command and that at least 75% of the trunks in this trunk group
are alarmed.
test port UUCSSpp l
Analog CO Trunk
CO-TRK
MINOR
test port UUCSSpp l
Analog CO Trunk
CO-TRK
WARNING
test port UUCSSpp l
Analog CO Trunk
TN438
TN2138
TN447
TN2147
TN465
TN2148
TN747