Справочник Пользователя для Lucent Technologies Release 7

Скачать
Страница из 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-520
DIOD-DS1 (DS1 DIOD Trunk) 
9
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Error Log Entries and Test to Clear Values
out-of-service
The trunk is in a deactivated state and cannot be used 
for either incoming or outgoing calls.
in-service
The trunk is in an activated state and can be used for 
both incoming and outgoing calls.
disconnect 
(ready-for-service)
The trunk is in an activated state but can only be used for 
an incoming call.
DS1 
DIOD
 Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk <grp>/<mbr>
1(a)
57408
1(a)
57487
57476
57477
57485
15(b)
Any
Port Audit and 
Update Test (#36)
18(c)
0
busyout trunk 
<grp>/<mbr>
WARNING
OFF
release trunk 
<grp>/<mbr>
130(d)
None
WARNING
ON
test trunk <grp>/<mbr>
257(e)
57392
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/MAJ
2
OFF
513(f)
57393
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/MAJ
2
OFF
769(g)
57484
1025(h)
51200
1025
DS1 CO Dial Tone 
Seizure Test (#314)
MIN/
WRN
3
OFF
test trunk <grp>/<mbr> 
r 2
1281
Conference Circuit 
Test (#7)
MIN/
WRN
3
ON
test trunk <grp>/<mbr> 
l r 4
1537
NPE Crosstalk Test 
(#6)
MIN/
WRN
3
ON
test trunk <grp>/<mbr> 
l r 3
1793(i)
test board UUCSS l
2049(j)
57473
57474
57475