DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-147
ASAI-RES/E-DIG-RES (TN800 reserve slot) 
9
ASAI-RES/E-DIG-RES (TN800 reserve 
slot)
There are no tests associated with these MOs. Both the test board and busy out 
board
 commands abort when either is attempted on a reserved slot. An error 
message indicates the slot is associated with the circuit pack that the TN800 is 
emulating, but the requested operation is not valid.
The TN800 MAPD (Multi-Application Platform for DEFINITY) circuit pack 
connects to the switch through a single slot in the backplane. The number of 
slots occupied by the MAPD pack is supplied by the board when inserted. The 
TN800 in R5EM is 3 slots wide. The TN800 requires 2 reserve slots to its left. The 
reserve (blank) slots are to left of the functional slot and are place holders on the 
switch, and do not have any interaction with the switch.
Each instance of these MOs represents a reserve slot associated with respective 
circuit pack mode in which the MAPD is working.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
Full Name of MO
ASAI-RES
NONE
NONE
TN800 ASAI reserve slot
E-DIG-RES
NONE
NONE
TN800 DIG reserve slot