Справочник Пользователя для Lucent Technologies Release 7

Скачать
Страница из 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-151
ATM-BCH (ATM B-Channel Trunk) 
9
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call 
state. Possible causes:
Received a DISConnect or RELease COMplete message with 
cause value 52 (outgoing calls barred)
Received a DISConnect or RELease COMplete message with 
cause value 54 (incoming calls barred)
Outgoing call renegotiated by the far end to another B-channel in 
the absence of SETUP message glare
Near end attempted a call on a B-channel that the far end has 
marked OOS
When running the Short Test Sequence, pay close attention to the results 
of the Call State Audit Test (#257).
Table 9-63.
ATM-BCH Error Log entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSppp
1(
a
)
Any
None
test port UUCSSppp
18
0
busyout trunk 
grp/mbr
release trunk grp/mbr
129 (
b
)
None
WNG
OFF
test port UUCSSppp
130 (
c
)
test port UUCSSppp
257(
d
)
Any
Service State Audit (Test 
#256)
test port UUCSSppp
513(
e
)
Any
None
WNG
OFF
test port UUCSSppp
769(
f
)
Any
Service State Audit (Test 
#256)
test port UUCSSppp
1793(
g
)
Any
None
test port UUCSSppp
3073(
h
)
Any
Service State Audit (#256)
test port UUCSSppp
3585(
i
)
Any
None
none
3841(
j
)
Any
None
WNG
OFF
none
Continued on next page