DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install Management Terminal and Activate System 
Page 3-24
Administer Fiber Links (Release 6r Only) 
3
Administer Fiber Links on Simplex Systems 
1. Administer the TN570 Expansion Interface and the TN574 or TN1654 DS1 
Converter circuit packs. Enter the change circuit packs command and 
press 
Enter
. See 
Screen 3-9
.
Screen 3-9.
Circuit Packs Form
2. Scroll through the pages on the form until the carrier containing the new 
circuit packs displays. Enter the circuit packs into the appropriate slot 
locations on the form. Press 
Enter
 when finished.
3. Enter the list fiber command. All administered fiber connections display. 
4. If a previously used fiber link is to be reused, enter the add fiber 
number>  command. If this is a new fiber link, enter the add fiber next 
command. The Fiber Link Administration screen appears. Use this form to 
administer fiber links, each of which is identified by a fiber number. 
5. Enter y or n in the field 
Is one endpoint remoted via DS1 
Converter complex?
 and press 
Enter
.
6. Enter the location of the TN570 and the TN574 or TN1654 circuit pack for 
both ENDPOINT-1 and ENDPOINT-2.
7. Scroll to page 2 of the form. Enter y as applicable, in each 
Facility 
Installed?
 field (A, B, C, and D). 
8. In the 
Bit Rate:
 field, enter either 1.544 (T1) or 2.048 (E1). 
9. Enter the idle code in the 
Idle Code MSB (1) . . . . LSB (8):
 
field. The default value is 11101000. It is recommended that the default 
value be used unless it becomes absolutely necessary to change it. The 
“MSB” means Most Significant Bit, the “LSB” means Least Significant Bit.