Test the System 
Page 4-6
Test SPE Duplication Memory Shadowing Link 
4
Test SPE Duplication Memory 
Shadowing Link
For high and critical reliability systems only.
1. Verify the screen displays: 
Command:
2. Type test shadow-link
 
and press 
Enter
.
3. Verify the screen displays test results similar to 
Screen 4-5
.
Screen 4-5.
Example Test Results for SPE Duplication Memory Shadowing Link
4. If result is 
FAIL
 for any test, check the inter-cabinet cables in the PPN.
                                  TEST RESULTS
   Port      Maintenance Name  Alt. Name Test No. Result            Error Code
             SHDW-LNK                    318      PASS
 Command successfully completed