Справочник Пользователя для Lucent Technologies Release 6

Скачать
Страница из 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-15
Adjunct Power Connections 
5
Local and Phantom Power
A console’s maximum distance from the system is limited. See 
Table 5-4
Auxiliary Power
!
CAUTION:
Do not use the 329A power unit for the attendant console.
The non-essential functions of an attendant console and its optional selector 
console derive their power from an auxiliary power source. Up to 3 consoles can 
use system power from through the auxiliary cable located in the trunk/auxiliary 
field. Provide auxiliary power for a primary attendant console through this cable 
so the console remains fully operational during short power outages.
NOTE:
For a console to realize the longest nominal battery holdover, the console’s 
TN754B or TN413 Digital Line circuit pack should reside in an EPN’s 
expansion control carrier.
An attendant console can also derive auxiliary power from either:
Individual 1151A or 1151A2 power supply
MSP-1 power  supply
258A-type adapters
Bulk power supplies such as the 1145A1 
A console’s maximum distance from its auxiliary power source is:
800 feet (244 m) for a 302A1
350 feet (107 m) for a 301B1 and 302C1
Table 5-4.
Attendant Console Cabling Distances
Enhanced Attendant 
Console (302C1) 
24 AWG Wire (0.26 mm
2
)
26 AWG Wire (0.14 mm
2
)
Feet Meters
Feet 
Meters
With Selector Console
Phantom powered
800
244
500
152
Locally powered
5000
1524
3400
1037
Without Selector Console
Phantom powered
1400
427
900
274
Locally powered
5000
1524
3400
1037