Install and Wire Telephones and Other Equipment 
Page 5-29
TN1654 DS1 Converter (Release 6r Only) 
5
E1 Interface Cabling
Figure 5-14
 shows typical E1 cabling to the network interface via the coaxial 
adapter cable. The actual adapter may be different in appearance.
Figure 5-14.
DS1 Converter Connections 
 
E1 Only
1. Connect a coaxial adapter cable to the remaining end of the “Y” cable. 
The opposite end of this cable is wired to a coaxial adapter assembly.
2. Plug a customer-provided quad cable onto the 4 BNC connectors 
provided on the coaxial adapter.
3. Connect the opposite end of the quad cable to the network interface.
Figure Notes
1. 50-Pin Male Connector on Coaxial Adapter Cable 
2. Coaxial Adapter Cable (With 8 BNC Connectors)
3. Connect to Quad Cable
4. Connect to E1 Network