Справочник Пользователя для Lucent Technologies Release 6

Скачать
Страница из 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-109
Add Multiple Announcement 
5
Add Additional TN750C Circuit Packs
1. Install the TN750C into a vacant slot in a carrier.
NOTE:
Any carrier is acceptable since power holdover is not a concern.
2. Administer a new data module on the TN750C circuit pack, as described 
in 
DEFINITY Enterprise Communications Server Release 6 Administration 
and Feature Description
.
3. Administer new announcements to that TN750C slot by executing the 
change announcements command and filling in the “designated board 
location” field for the circuit pack’s location.
4. Record the announcements, as described in 
DEFINITY Enterprise 
Communications Server Release 6 Administration and Feature 
Description
.
5. Wait until the announcements copy from voice RAM to the on-board flash 
memory (the yellow LED on the TN750C starts and then stops flashing). 
This may take about 10 minutes.
Move a Single Announcement from 1
Announcement Circuit Pack to Another
1. Execute the change announcements command to change the circuit 
pack locations of a particular announcement. You may also change the 
compression rate at this time.
2. Rerecord the announcement, as described in 
DEFINITY Enterprise 
Communications Server Release 6 Administration and Feature 
Description
.