Install and Wire Telephones and Other Equipment 
Page 5-125
Add PRI Over PACCON to R6si 
5
Service Interruption
1. Since the addition of PRI Over PACCON requires a service interruption, 
notify the customer in advance as to when the addition will take place.
Disable Alarm Origination
1. Enter change system-parameters maintenance and press 
Enter
2. Set the
 Alarm Origination Activated 
field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble tickets. 
3. For some releases of software, disable 
Cleared Alarm Notification
 
and 
Restart Notification
 before submitting the form.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
Enter
 to verify that the system is in the “active/standby” mode.
2. Enter save translation and press 
Enter
. This instructs the system to take all 
translation information in memory and write it to the translation card or 
tape.
3. If the system contains a TN750 Announcement circuit pack, enter display 
announcements and press 
Enter
If administered recorded announcements are listed, enter list 
configuration software-version
 press 
Enter
. To save the announcements, 
enter save announcements and press 
Enter.
Power Down System
If the packet bus is being added:
1. At the PPN, set the main circuit breaker to OFF.
2. At each EPN, set the main circuit breaker to OFF.
Add Circuit Packs
1. To control every ISDN-PRI link in the system, a TN778 Packet Control 
circuit pack and TN464 ISDN-PRI circuit packs are required.