DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-129
Add PRI Over PACCON to R6si 
5
2. The system performs a reset level 4 reboot, loading translations from the 
translation card. Rebooting requires 8 to 11 minutes.
3. Login at the 
login:
 prompt on the management terminal, and set the 
time to ensure that the system is booted properly.
4. Enter list configuration software-version and press 
Enter
 to compare the 
version number of the software program (displayed on the terminal) with 
the TN790 version number (written on a label on the TN790’s faceplate). If 
the version numbers are not the same, change the version number on the 
TN790 label so that they agree.
NOTE:
Certain forms have changed for Release 6. Upgraded translations 
may appear on a different form, fields may shift within a form, or the 
names assigned to particular fields may change. Refer to 
DEFINITY 
Enterprise Communications Server Release 6 Transition Reference
and 
DEFINITY Enterprise Communications Server Release 6 
Administration and Feature Description
, and make the necessary 
changes.
Enable Customer Options
1. Enter change system-parameters customer-options and press 
Enter
.
2. Use these forms to verify the customer options are properly set.
NOTE:
If the customer was using Supplementary Services Protocol “b” or 
“d” on an ISDN-PRI trunk group before the upgrade, set the 
Basic 
Call Setup 
field to y.
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 6 Maintenance for R6r