Install Telecommunications Cabling 
Page 2-23
Cable Installation 
2
Connect Trunk Pairs to Cabinet Using Jumper
Wires To Establish 3-Pair Modularity
Figure 2-13 on page 2-23
 and 
Figure 2-14 on page 2-24
 show trunk pairs 
connected to the cabinet with jumper wires to establish 3-pair modularity.
Figure 2-13.
3-Pair Modularity for Trunk Pairs for 1-Pair Trunks
To connect the trunk pairs to the purple field:
1. Connect B25A cables between the network interface and the sneak fuse 
panels. See 
Figure 2-13
.
2. Connect A25D/B25A cables from the sneak fuse panels to the 110-type 
terminal block-type connecting block connectors in the green field.
3. Connect 1-pair patch cords/jumper wires from each 110-type terminal 
block row in the green field to the 110-type terminal block rows in the 
purple field for 1-pair Central Office (CO) trunks or in 
Figure 2-14 on page 
2-24
 for 3-pair tie trunks.
Figure Notes:
1. Green Field 
2. 1-Pair Jumpers
3. Pairs