Справочник Пользователя для Exabyte 1X7 LTO
![Exabyte](https://files.manualsbrain.com/attachments/9bb6aba5fd295dcce41fcac7b330c2e20f0d5b68/common/fit/150/50/87e4ae6bd262aebea75ffc62de20558415385c9c9e8c6457c7cbe4850cf6/brand_logo.jpeg)
132
P
RODUCT
M
ANUAL
1012581
A
PPENDIX
B—W
RITE
O
NCE
, R
EAD
M
ANY
(WORM) C
APABILITY
E
RROR
C
ODES
Tape drive errors associated with the new WORM capability result in either a
Medium Error (Sense Key 3h) or a Data Protect error (Sense Key 7h). The tape
drive returns this error information in response to a SCSI REQUEST SENSE
command. Refer to the tape drive SCSI reference for additional information
about the error codes returned by the REQUEST SENSE command.
shows the new ASC/ASCQ error codes for Sense Key 3h (Medium
Error).
shows the new ASC/ASCQ error codes for Sense Key 7h (Data
Protect).
Table B-3 ASC/ASCQ error codes for a Medium Error (SK 3) with WORM media
ASC
ASCQ
Description
04h
10h
Logical Unit Not Ready, Auxiliary Memory Not Accessible.
11h
12h
Auxiliary Memory Read Error
30h
0Dh
Medium Error/WORM Medium – Integrity Check
: Set when the drive rejects a
Read operation because the current cartridge is a Suspicious WORM cartridge,
and the WTRE bit is set to 0.
Table B-4 ASC/ASCQ error codes for a Data Protect error (SK 7) with WORM media
ASC
ASCQ
Description
30h
0Dh
Data Protect/WORM Medium – Integrity Check
: Set when the drive rejects a
Write operation because the current cartridge is a Suspicious WORM cartridge.
30h
0Ch
Data Protect/WORM Medium – Overwrite Attempted
: Set when the drive
rejects a Write operation because the rules for allowing WORM writes have not
been met.