SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING
33
Troubleshooting
NOTE: If problems are not remedied by the suggested means above, contact an ICCG dealer or 
technical support.
SYMPTOMS
FAULTS
SOLUTION
Hydromassage System
System will not start.
No electrical power to tub.
Check and reset breaker.
System not prepared.
Be sure water level is ABOVE jets.
Check that inlet plug on tub is depressed.
Switch hose disconnected
Reconnect hose to switch and motor.
System is ineffective.
Water deposits in whirlpool jets. Disassemble and clean whirlpool jets.
Whirlpool jets closed.
Open whirlpool jets.
Aerator closed.
Open aerator.
Whirlpool intake clogged.
Inspect intake and remove obstruction.
Tub Operation
No water flow.
Water supply turned off.
Turn on water supply.
Restricted water flow.
RADA valve. Refer to RADA 
owner’s manual
Inspect and clean RADA valve.