Справочник Пользователя для Subaru Robin Power Products RGV6100

Скачать
Страница из 82
66 
-
(3) Check the insulation resistance between sta-
tor core and each stator lead using a Dr. Robin
generator tester in megger tester mode or a
megger tester. (Fig. 2-3)
If insulation is bad, replace stator with a new
one.
2-1-3 CHECKING ROTOR
(1) Remove rear cover and stator.
(2) Using a Dr. Robin or a circuit tester, measure
the resistance of the field coil at the terminals.
NOTE : Because a diode is soldered to the coil
ends at the terminals, resistance may be mea-
sured only when tester probes touch the termi-
nals in one combination of polarity. Therefore, if
no resistance reading appears, try checking in
reverse polarity.
[Remedy]
If the resistance is not normal, replace rotor with
a new one.
Fig. 2-3
Fig. 2-4
Fig. 2-5
Table. 2-3
(
Ω
)
L
E
D
O
M
1
0
1
4
V
G
R
1
0
1
6
V
G
R
E
C
N
A
T
S
I
S
E
R
5
8
.
4
Ω
3
.
5
Ω