Справочник Пользователя для Desa PD15EA

Скачать
Страница из 16
www.desatech.com
113612-01B
5
CLEANING
DURING SEASON CARE
Always  unplug  the  product  before  moving  or 
cleaning.
1.  Do not disassemble. Carefully wipe the exte-
rior of unit with a soft, damp cloth.
2.  After cleaning, be sure to completely dry the 
unit with a cloth or towel.
AFTER SEASON CARE
Store product indoors in a dry location. No main-
tenance is required for this product.
TROUBLESHOOTING
  CAUTION:  Risk  of  electric 
shock. Do not open. No user servi-
cable parts inside. Take heater to 
an authorized service center.
If your product fails to operate:
1.  Make sure the electrical outlet GFCI or circuit 
breaker and extension cord is working. 
2.  Check for operation of tip switch. The ON/
OFF switch light can be on but the tip switch 
OFF. Move product until a “click” is heard. 
To prevent damage of tip switch post, do not 
slide product.
3.  Look for obstructions around fan. If you find 
an  obstruction,  turn  the  product  OFF  and 
UNPLUG THE PRODUCT. Have the product 
serviced by a qualified individual.
4.  Check for tripped thermal protector. Motor 
and heating element do not operate. Wait 10 
minutes for product to cool. Push reset button. 
See Thermal Limit Switch below.
THERMAL LIMIT SWITCH
If product is used in temperatures below 75° F 
(28.9°  C),  the  limit  switch  should  not  require 
resetting unless there is a malfunction. If a mal-
function does occur, have the product serviced by 
an authorized service center.
Resetting Thermal Limit Switch
1.  Unplug product.
2.  Allow product to cool.
3.  Turn product upside down.
4.  Remove plug on bottom.
5.  Insert provided plastic push rod through hole 
and  guide  to  small  red  button  on  thermal 
limit switch (see Figure 4). A flashlight will 
improve visability.
6.  Lightly push red button to reset switch.
7.  Replace removed plug in hole. Perform a trial 
operation.
8.  If repeated resetting of the thermal limit switch 
is required, have the product serviced by an 
authorized service center.
POWER PLUG
120V 60Hz
GREEN
BLACK
N
L
N
L
WHITE
ON/OFF
SWITCH
HEATING
ELEMENT
MOTOR
BLACK
MANUAL RESET
THERMAL LIMIT
SWITCH
TIP SWITCH
BLACK
GREEN
BLACK
BLACK
WHITE
WHITE
WIRING DIAGRAM
Access to 
Thermal 
Limit Switch
Figure 4 - Resetting Thermal Limit Switch
Push Rod