Справочник Пользователя для Mitsubishi Electronics QD64D2
4
- 10
4.5 Intelligent Function Module Switch Setting
4
PROCEDURES AND SETTINGS BEFORE
OPERATION
4.5
Intelligent Function Module Switch Setting
This section describes the intelligent function module switch setting.
The switch setting is made on the [I/O assignment] screen of GX Developer.
The switch setting is made on the [I/O assignment] screen of GX Developer.
(1) Intelligent function module switch setting
The switch has five switches and is set at 16-bit data.
When the switch setting is not made, the default values of the switches from 1 to 5 are
0.
When the switch setting is not made, the default values of the switches from 1 to 5 are
0.
Table 4.5 Intelligent function module switches
Setting item
Setting value
Default
Switch 1
(CH1)
(CH1)
1) Pulse input mode
0
0
H
: 1 multiple of 1 phase
1
H
: 2 multiples of 1 phase
2
H
: CW/CCW
3
H
: 1 multiple of 2 phases
4
H
: 2 multiples of 2 phases
5
H
: 4 multiples of 2 phases
0000
H
2) Counter format
0
0
H
: Linear counter
1
H
: Ring counter
3) Counter value comparison
function election
0
function election
0
H
: Coincidence output function
1
H
: Continuous comparison
function
Switch 2
(CH2)
(CH2)
Same as for the switch 1
0000
H
Switch 3
Reserved: Fixed to 0
Switch 4
Reserved: Fixed to 0
Switch 5
Reserved: Fixed to 0
1)
Reserved:
Fixed to 0
Fixed to 0
2)
b8
b11
Reserved:
Fixed to 0
Fixed to 0
3)
b12
b15
Reserved:
Fixed to 0
Fixed to 0