Справочник Пользователя для Datalogic Scanning DX30

Скачать
Страница из 197
REFERENCES 
5.5 READING 
PARAMETERS 
 
5.5.1 
Hardware Trigger Mode 
 
This mode determines how the reading phase is controlled when the hardware trigger 
operating mode is selected: 
•  trigger active level: the reader goes ON when the trigger is pressed and goes 
OFF when it is released 
•  trigger active pulse: the reader goes ON at the first trigger press and goes OFF 
only at a second press 
 
 
5.5.2 Trigger-Off 
Timeout 
 
When this timeout is selected, the reader turns OFF automatically after the desired 
period of time. 
 
 
5.5.3 
Reads per Cycle 
 
In general, a reading cycle corresponds to the ON + OFF times of a device. 
The resulting effects of this parameter on code reading depend on other related 
configuration conditions. Here are the definitions of ON and OFF times. 
 
• 
For readers using the software trigger parameter (FLASH MODE), a reading 
cycle corresponds to the flash on + flash off times. Code reading takes place 
during the flash on time. 
• 
For readers using the hardware trigger parameter, a reading cycle corresponds 
to a trigger press (ON) + one of the following OFF events: 
trigger release (for trigger active level
a second trigger press (for trigger active pulse
trigger-off timeout (see par. 5.5.2). 
 
When one read per cycle is selected, the device decodes only one code during the 
ON period and immediately turns the reader OFF. It is only possible to read another 
code when the next ON time occurs. 
 
In  multiple reads per cycle, the ON period is extended so that the device can 
continue decoding codes until an OFF event occurs. For software trigger mode, the 
flash on period is immediately reset after each read and therefore extended. If 
another code is decoded before the reset flash on period expires, it is again reset and 
the effect is that the device remains ON, decoding codes until the flash on or timeout 
period expires. 
The Safety Time parameter should be used in this case to avoid unwanted multiple 
reading of the same code, see par. 5.5.4. 
 
149