4.  Parameters (User) 
4.2  Machining Parameters 
 
 
 
I-155 
4.2.3  Axis Parameters 
 
 
 [AXIS PARAMETER] 
PARAM  1.6/8 
 
 
<X> <Y> <Z>  <C> 
 8201  AX. RELEASE 
 8202  OT-CHECK OFF 
 8203  OT-CHECK-CANCEL 
 8204  OT-CHECK-N 
1.000 
1.000 
1.000 
1.000 
 8205  OT-CHECK-P 
1.000 
1.000 
1.000 
1.000 
 8206  TOOL CHG.P 
0.000 
0.000 
0.000 
0.000 
 8207  G76/87 IGNR 
 8208  G76/87 (-) 
 8209  G60SHIFT 
0.000 
0.000 
0.000 
0.000 
 8210  OT INSIDE 
 8211 
 8212 
 
 # (      ) 
DATA(     ) 
(     ) 
(     ) 
(     ) 
 
 
WORK 
PROCESS 
I/O PAR 
SETUP 
MENU 
 
 
# Item 
Contents 
Setup 
range 
(unit)
8201  AX. RELEASE 
Select the function to remove the control axis from 
the control target. 
0:  Control as normal.  
1:  Remove from control target. 
0/1 
8202  OT-CHECK OFF 
Select the stored stroke limit II function set in #8204 
and #8205. 
0:  Stored stroke limit II valid  
1:  Stored stroke limit II invalid 
0/1 
8203  OT-CHECK-CANCEL
When the simple absolute position method (#2049 
type is 9) is selected‚ the stored stroke limits I, II (or 
IIB) and IB will be invalid until the first zero point 
return is executed after the power is turned ON. 
0:  Stored stroke limit II valid (according to 
#8202) 
1:  Stored stroke limit II invalid 
Note: Temporary cancel of #8203 soft limit affects 
all the stored stroke limits. 
0/1 
8204  OT-CHECK-N 
This sets the coordinates of the (–) direction in the 
moveable range of the stored stroke limit II or the 
lower limit coordinates of the prohibited range of 
stored stroke limit IIB. 
If the sign and value are the same as #8205, the 
stored stroke limit II (or IIB) will be invalid. 
If the stored stroke limit IIB function is selected, the 
prohibited range will be between two points even 
when #8204 and #8205 are set in reverse.  
When II is selected, the entire range will be 
prohibited. 
±99999.999 (mm)