Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
4.  Operation Mode 
4.1  Mode Selection Switch 
 
 
 
II-7 
4.  Operation Mode 
 
 (Note 
) Do not execute the tap retract simultaneously with the operation in the manual (JOG feed, rapid 
traverse feed, reference position return, incremental and handle) mode or in the automatic (memory, 
tape and MDI) mode. 
The simultaneous operation causes the all axes interlock. 
 
4.1  Mode Selection Switch 
 
 
The MODE SELECT switch is used to determine the controller operation mode. 
 
Jog feed mode: 
Select the mode to move the controlled axis 
consecutively at manual feedrate.
 
Rapid traverse feed mode: 
Select the mode to move the controlled axis 
consecutively at rapid traverse feedrate.
 
Return to reference position mode: 
Select the mode to position the controlled axis 
at the machine reference position manually.
 
Incremental mode: 
Select the mode to move the controlled axis at a 
given distance. 
MODE SELECT MEMORY 
RAPID 
TRAVERSE 
JOG 
REFERENCE 
POINT 
 
RETURN 
MDI
TAPE
HANDLE
INCRE-
MENTAL
 Handle 
feed 
mode: 
 
 
Select the mode to move the controlled axis by using the manual handle. 
 Memory 
Mode: 
 
 
Select the mode for memory operation. 
 Tape 
mode: 
 
 
Select the mode for tape operation. 
 MDI 
mode: 
 
 
Select the mode for MDI operation. 
 (Note 
1)  See 1.4 for the running state when a change is made to another mode during automatic 
operation. 
 
 
4.2  Jog Feed Mode 
 
 
The jog feed mode enables the machine to be moved consecutively at the feedrate set by using the 
MANUAL FEED RATE switch manually. The jog feed mode is started by using the FEED AXIS SELECT 
switch. 
 
See Section 5 for the MANUAL FEED RATE switch. 
 
 Operation 
procedure 
Using the MODE SELECT switch, select the jog mode. 
 
Using the MANUAL FEED RATE switch, set the feedrate. 
The feedrate unit is the travel distance (mm) per minute. 
 
To move the controlled axis, turn on the FEED AXIS SELECT switch. The 
controlled axis is moved while the switch is turned on. 
When the switch is turned off, the controlled axis stops with deceleration. 
 
 
 (Note 
1)  When the MANUAL OVERRIDE switch on the operation panel is turned ON, the override value set 
by using the FEED RATE OVERRIDE switch takes precedence over the feedrate set by using the 
MANUAL FEED RATE switch.