6.  Operation Panel Switch Functions 
6.9  Manual Absolute 
 
 
 
II-20 
6.9  Manual Absolute 
 
 
When the MANUAL ABSOLUTE switch is turned ON, the program coordinate system is updated by manual 
tool move distance. If the switch is OFF, the program coordinate system is updated by manual tool move 
distance. 
 
 
 
 
-Y 
X
When MANUAL ABSOLUTE Switch Is ON
Passes through the same path as program.
Path after manual interrupt 
(Program coordinate system is updated by tool 
move distance.) 
Manual interrupt 
Path on program 
(absolute command) 
Feed hold stop 
 
 
 
 
 
 
 
-Y 
X
When MANUAL ABSOLUTE Switch Is OFF
Path is shifted by manual interrupt value. 
(Origin (zero) is moved.) 
Path after manual interrrupt
(Program coordinate system is not updated.) 
Manual interrupt 
Path on program   
(absolute command) 
Feed hold stop