Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
6.  Operation Panel Switch Functions 
6.14  Handle Interruption 
 
 
 
II-23 
6.14.4  Axis Movement Speed Resulting from Interruption 
 
 
(1)  The movement speed of the axis for which handle interruption is executed, may exceed the rapid 
traverse feed rate during rapid traverse feed command (G00) processing in automatic start. To prevent 
this, clamp the axis. (The movement speed equals Automatic-start movement speed + Speed resulting 
from manual handle interruption.) 
 
(2)  The movement speed of the axis for which handle interruption is executed, may exceed the cutting feed 
speed during cutting feed command (G01, G02, G03) processing in automatic start. To prevent this, 
clamp the axis. (The movement speed equals Automatic start movement speed + Speed resulting from 
manual handle interruption.) 
 
(3)  If, during automatic start, manual handle interruption is executed, in the same direction, for the axis that 
is moving at an external decelerating speed, the axis movement speed may exceed the external 
decelerating speed. To prevent this, clamp the axis. (The movement speed equals Automatic start 
movement speed + Speed resulting from manual handle interruption.) 
 
(4)  If an attempt is made to execute interruption at a speed exceeding the clamp speed, the reading on the 
handle scale does not match the distance of interruption. 
 
(5)  The handle scale factor depends on the selected input of the manual handle/step scale factor.