6.  Operation Panel Switch Functions 
6.16  Deceleration Check 
 
 
 
II-34 
6.16.4  Parameters 
 
 
(1)  Designation of deceleration check 
 
 
Base specification parameters 
# Items 
Details 
Setting 
range 
inpos 
Change with the "#1306 InpsType deceleration check designation 
type". 
0:  Deceleration check method 
1:  Validate in-position check  
 
 Deceleration 
check 
method 1 
Select the G0 deceleration check method. 
0:  Command deceleration check 
1: In-position 
check 
0/1 
1193 
 Validate 
in-position 
check 
Designate the deceleration confirmation method for the 
positioning and cutting command. 
0: G0, G1+G9  Command deceleration check 
1: G0, G1+G9  In-position check 
0/1 
1223 aux07 
(bit1) 
Deceleration 
check 
method 2 
Select the deceleration check method for G1 + G9. 
0:  Command deceleration check when G1+G9 
1:  In-position check when G1+G9 
Deceleration check is executed only for G1+G9. 
If the #1306 InpsType deceleration check designation 
type is "1" (deceleration check designation type 2), this 
parameter will be invalid. 
0/1 
1306 InpsTyp  Deceleration 
check 
specification 
type 
Select the parameter specification type for the G0 or G1 
deceleration check. 
0:  Deceleration check specification type 1 
G0 is specified with “#1193 inpos”, and G1+G9 
with “#1223 aux07/BIT1”. 
1:  Deceleration check specification type 2 
G0 or G1+G9 is specified with “#1193 inpos”. 
0/1 
 
 
(2)  Deceleration check during opposite direction travel 
 
 
Base specification parameters 
# Items 
Details 
Setting 
range 
1502 G0Ipfg  G1 
→ G0 
deceleration 
check 
0:  Do not perform a deceleration check when the 
move direction is changed from G1 to G0. 
1:  Perform a deceleration check when the move 
direction is changed from G1 to G0.   
0/1 
1503 G1Ipfg  G1 
→ G1 
deceleration 
check 
0:  Do not perform a deceleration check when the 
move direction is changed from G1 to G1. 
1:  Perform a deceleration check when the move 
direction is changed from G1 to G1.   