Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
5.  Stored Stroke Limit 
5.3  Stored stroke limit IB 
 
 
 
III-33 
5.3  Stored stroke limit IB 
 
The boundary is set for each axis with the parameters (axis parameters "#2061 OT_1B–" and "#2062 
OT_1B+"). The inside of the set boundary is the prohibited range. 
 
 
Range prohibited 
with stored stroke 
limit IIB
 
Basic 
machine 
coordinate 
system
 
Point 1 
P
rohi
bi
te
d range
 
Machine 
movement 
valid range
– setting value
+ setting value
P
rohi
bi
te
d range
 
Point 2 
Point 3 
Point 4 
Point 6 
Point 5 
 
 
 
 
5.4  Stored stroke limit IC 
 
The boundary is set for each axis with the parameters (axis parameters "#2061 OT_1B–" and "#2062 
OT_1B+"). The inside of the set boundary is the machine movement valid range. 
This is valid when the axis parameter #2063 is set to 2, and cannot be used with soft limit IB. 
 
Basic machine coordinate system
 
Point 1 
P
rohibi
ted range
 
 
Machine movement valid range
 
P
rohibi
ted range
 
Point 2 
Point 3 
Point 4 
Additional 
movement 
range 
 
 
The following values are set 
with the coordinate values in 
the basic machine coordinate 
system. 
Point 3 : #2062 OT_1B+ 
Point 4 : #2061 OT_1B– 
 
Points 1 and 2 are the 
prohibited range set with stored
stroke limit I, and points 3 and 4
are the prohibited range set 
with stored stroke limit II. 
The following values are set 
with the coordinate values in 
the basic machine coordinate 
system. 
Point 3 : #2062 OT_1B+ 
Point 4 : #2061 OT_1B– 
 
Points 1 and 2 are the 
prohibited range set with 
stored stroke limit I.