Справочник Пользователя для IBM 500

Скачать
Страница из 63
SurePOS 500 4846-XX5 Technical Reference 
Page 35 of 63 
4.0 Environmental 
Specifications 
4.1 Temperature/Humidity 
Limits 
Condition 
Temp Limits (Dry Bulb) 
Relative Humidity 
Max. Wet Bulb Temp 
Operating / Standby 
5 to 40° 
8 to 80 % 
27°C 
Storage (packaged) 
0 to 60°C 
5 to 80 % 
29°C 
Shipment (packaged) 
-40 to 60°C 
5 to 100 % 
29°C 
4.2 Altitude 
Limits 
The product is designed to operate up to 3050 meters (10,000 feet).  
4.3 Power 
Off (attached to mains) 
4W 
Suspend Not 
supported 
Standby 80W 
On (idle) 
120W 
Power Consumption 
(system) 
On (max) 
170W 
Input Voltage 
100 - 127, 200 - 240 VAC (nominal), 50 or 60 Hz (+/- 3 Hz) 
Sinusoidal, trapezoidal, or square wave inputs 
kVA 0.3 
AC Input Connector/Cable 
IEC 320 C14, unshielded right angle type 
Leakage current 
3.5 mA maximum 
Inrush 
< 30 A (peak, first cycle) 
4.4 Acoustics 
Measurement Operator 
-Idle 
LwAu (bels) 
5.0 
All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296. 
4.5 Standards 
Compliance 
4.5.1 Product 
Certifications 
Category Standard 
External Safety 
• IEC 
60950-1 
1
st
 Edition with all national deviations 
•  UL 60950-1 1
st
 Edition 
•  CAN/CSA C22.2 No. 60950-1 3
rd
 Edition 
• CCC 
(China) 
• IRAM 
(Argentina) 
• PSE 
(Japan) 
• GOST 
(Russia) 
• BSMI 
(Taiwan) 
 
Electrostatic Discharge (ESD) 
EN 55024:1998 (EN 61000-4-2:1995)