3 - 3
 
 
3.2  Parameter 
The parameters are basic setting values applied to a programmable controller in 
order to control objects as planned. 
The parameters are divided into the PLC parameter, network parameter, and remote 
password as shown below. 
 
* A shaded area in the following table indicates the items to be set in this textbook. 
Item Description 
Label 
Sets a label (name and application) of a programmable controller CPU. 
PLC name 
Comment 
Sets a comment for the label of a programmable controller CPU. 
Timer limit setting 
Sets the time limit of the low-speed or high-speed timer. 
RUN-PAUSE contacts 
Sets contacts for controlling RUN and PAUSE of a programmable controller CPU. 
Latch data backup operation 
valid contact 
Sets contact devices in order to execute the latch data backup operation. 
(Only for Universal model QCPU) 
Remote reset 
Sets whether to allow a remote reset operation from GX Works2. 
Output mode at STOP to 
RUN 
Sets the status of an output (Y) when the programmable controller is switched from STOP 
to RUN. 
Floating point arithmetic 
processing 
Sets whether to execute floating-point processing in double precision. 
(Only for high performance model QCPU) 
Intelligent function module 
setting 
•  Sets the interruption pointer assignment of a module. 
•  Sets the start I/O number and start SI number. 
Common pointer No. 
Sets the start number of the pointer used as a common pointer. 
Points occupied by empty 
slot 
Sets the number of empty slots for the main or extension base unit. 
System interrupt settings 
•  Sets the start number of the interrupt counters. 
•  Sets the execution interval for the interrupt pointers. 
Interrupt program/fixed scan 
program setting 
Set whether to execute high-speed execution of an interrupt program. 
Module synchronization 
Set whether to synchronize the start-up of the programmable controller CPU with that of the 
intelligent function module. 
A-PLC compatibility setting 
Set whether to use the MELSEC-A series special relays/special registers. 
Service processing setting 
Sets the processing time and the number of times of service processing. (Only for Universal 
model QCPU) 
PLC system 
PLC module change setting 
Set this parameter to replace the CPU module using a memory card (Only for Universal 
model QCPU). 
File register 
•  Sets the file register file to be used in a program. 
•  Sets whether to transfer data to the standard ROM at a latch data backup operation. 
(Only for Universal model QCPU) 
Comment file used in a 
command 
Sets the device comment file to be used in a program. 
Initial device value 
Sets the device initial value file to be used on the programmable controller CPU. 
File for local device 
Sets the local device file to be used in a program. 
PLC file 
File used for 
SP.DEVST/S.DEVLD 
instruction 
Sets the device data ROM write/read instruction file to be used in a program. 
(Only for Universal model QCPU) 
WDT (watchdog timer) 
setting 
Sets the WDT of the programmable controller CPU. 
Error check 
Sets whether to detect specified errors. 
Operation mode when there 
is an error 
Sets the programmable controller CPU operation mode when an error is detected. 
Constant scanning 
Sets the constant scan time. 
Breakdown history 
Sets the storage destination for error histories of the programmable controller CPU. (Only 
for high performance model QCPU) 
PLC parame
ter 
PLC RAS 
Low speed program 
execution time 
Sets the execution time of a low-speed program in every scan. (Only for high performance 
model QCPU)