Справочник Пользователя для Pelco cm6800-322x6
28
C1522M-C (2/05)
CONNECTING GENEX MULTIPLEXERS
Use COM 4 to connect up to eight Genex Multiplexers to the CM6800-32X6.
1.
Connect the COM IN port of the multiplexer to COM 4 on the CM6800-32X6, using the 6-foot (1.8 m) reversed data cable supplied
with the CM6800.
with the CM6800.
One reversed cable and two straight cables are supplied with the CM6800 (save the reversed cable for connecting a Genex
multiplexer, if applicable).
multiplexer, if applicable).
A straight data cable is supplied with the Genex multiplexer. Use this cable for connecting a second Genex multiplexer to the first
multiplexer, if necessary.
multiplexer, if necessary.
2.
Connect the MAIN monitor output from the multiplexer to any of the camera inputs on the CM6800-32X6.
3.
Connect cameras to the multiplexer and then loop them to the CM6800. Refer to the MX4000 Genex Series Simplex and Duplex
Multiplexers Installation/Operation Manual for detailed camera connection instructions. Terminate the video loop at the CM6800.
Multiplexers Installation/Operation Manual for detailed camera connection instructions. Terminate the video loop at the CM6800.
4.
If required, you can connect a total of eight Genex multiplexers through COM 4. Daisy-chain the multiplexers by connecting a
straight data cable from the COM OUT port on the first multiplexer to the COM IN port on the second multiplexer; connect the COM
OUT port on the second multiplexer to the COM IN port on the third multiplexer. Continue to the eighth multiplexer, if necessary.
straight data cable from the COM OUT port on the first multiplexer to the COM IN port on the second multiplexer; connect the COM
OUT port on the second multiplexer to the COM IN port on the third multiplexer. Continue to the eighth multiplexer, if necessary.
Refer to the
System Start-Up section for additional configuration steps required when using a Genex Multiplexer.
Figure 22. Connecting Genex Multiplexers
COM 1
2
3
4
5
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
6
5
4
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
3
2
1
120/230V~
50/60 HZ
25 WATTS
1 2 3 4 5 6 7 8
CONTROL
T
+
T
-
R
+
R
-
HZ
75
2
VCR
AUX
MAIN
SPOT
SVHS
OUT
IN
SVHS
IN COM OUT N N
H
O C C S
ALARMS
1 2 3 4 5
6 7 8 9 10 11
14 15 16
12 13
110-240V 50/60 Hz
VCR
AUX
MAIN
SPOT
SVHS
OUT
IN
SVHS
IN COM OUT N N
H
O C C S
ALARMS
1 2 3 4 5
6 7 8 9 10 11
14 15 16
12 13
110-240V 50/60 Hz
VCR
AUX
MAIN
SPOT
SVHS
OUT
IN
SVHS
IN COM OUT N N
H
O C C S
ALARMS
1 2 3 4 5
6 7 8 9 10 11
14 15 16
12 13
110-240V 50/60 Hz
GENEX MULTIPLEXER
RJ-45 PIN-OUTS
Rx+
Rx-
NC
NC
GROUND
NC
Tx-
Tx+
Rx-
NC
NC
GROUND
NC
Tx-
Tx+
CM6800-32X6 COM 4
RJ-45 PIN-OUTS
GENEX MULTIPLEXERS-8 MAXIMUM
GENEX MULTIPLEXER
GENEX MULTIPLEXER
GENEX MULTIPLEXER
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
REVERSED CABLE
MONITOR SIGNAL OUT
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
Rx+
Rx-
12VAC (OUT)
12VAC
12VAC
GROUND
NC
Tx-
Tx-
Tx+
(OUT)
STRAIGHT CABLE
STRAIGHT CABLE
010101