Справочник Пользователя для Toshiba M30-35
3 Tests and Diagnostics
3.20 Log Utilities
3.20.2 Operations
1. Selecting
5
and pressing
Enter
in the DIAGNOSTIC MENU, logs error information
into RAM or onto a floppy disk. The error information is displayed in the following
format:
format:
XXXXX ERRORS
CNT TS-NO PASS
STS ADDR
WD
RD HSTS [ERROR STATUS NAME]
001 FDD 02 0000 103 00001 00 00 0000 FDD-WRITE PROTECTED
001 FDD
01 0000 180 00001 00
00 0000 FDD-TIME OUT ERROR
Error count
Pass count
Error status
Address
Subtest number
Test name
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
2. The error information displayed on the screen can be manipulated by the following
number keys:
The
1
key scrolls the display to the next page.
The
2
key scrolls the display to the previous page.
The
3
key returns to the Diagnostic Menu.
The
4
key erases all error log information in RAM.
The
5
key outputs the error log information to a printer.
The
6
key reads the log information from a floppy disk.
The
7
key writes the log information to a floppy disk.
3. In the case of “error retry OK,” a capital “R” will be placed at the beginning of the
error status. However, it is not added to the error count.
Error status name
Read data
Write data
HDC status
3-40
Satellite M30-35 Maintenance Manual (960-455)