DC8151101-00 C
B-1
Appendix B
SCSI Termination
B.1
Setting the SCSI Termination
The first and last physical SCSI devices on each end of the SCSI bus must be 
terminated. 
Termination is set automatically through Fast!UTIL 
. The 
QLA12160 board offers the additional option of terminating with jumpers 
Some cables have multiple connectors for connecting several devices to one of the 
board’s connectors. If the board uses a connector that is not on either end of the 
cable, then the board is not at one end of the SCSI bus and you need to change 
the termination setting. 
The following sections describe how to set termination for the QLA12160 board. 
The text and illustrations describe multiple SCSI devices daisy chained onto a single 
connector on the board. When daisy chaining narrow and wide SCSI devices, 
always have a wide SCSI device at the end of the chain.
NOTE: QLogic recommends using external termination in system configurations 
with multiple initiators that share the same SCSI bus (such as in Microsoft 
cluster configurations). External termination ensures proper device 
operation during power cycles. When external termination cannot be 
provided, terminate all host bus adapters using jumpers 
B.2
Termination (Jumpers) for the QLA12160
The QLA12160 board comes from the factory with jumpers on pins 1–2 of J5, J6, 
J7, and J8; these settings allow automatic termination 
Moving the jumpers on J5 and J6 on the QLA12160 board manually sets the 
termination for port one. Moving the jumpers on J7 and J8 on the QLA12160 board 
manually sets the termination for port two 
. Settings made with these 
jumpers override all Fast!UTIL or automatic termination settings.