DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-67
High Reliability 
5
Boot the Release 8 System
1. Connect the management terminal to the “TERMINAL” connector behind 
PPN control carrier “A,” or install the G3-MA according to the “Set Up 
G3-MA” chapter of 
DEFINITY Communications System Generic 3 
Management Applications 
 Operations, 585-229-202.
2. Insert the translation cards in the TN794 faceplates.
3. At each EPN power distribution unit, set the main circuit breaker to ON.
4. At the PPN power distribution unit, set the main circuit breaker to ON.
5. The system performs the reset level 4 rebooting process, loading the 
default system translations from the translation card. This takes 8 to 11 
minutes.
6. Get the order number of the upgrade, and call the regional CSA to request 
an “init” login so the right-to-use options can be enabled on the upgraded 
system.
7. To use Access Security Gateway (ASG), see 
Set Daylight Savings Rules
You can set up to 15 customized daylight savings time rules. If you have cabinets 
in several different time zones, you can set up rules for each on a location basis. 
A daylight savings time rule specifies the exact time when you want to transition 
to and from daylight savings time. It also specifies the increment at which to 
transition. 
NOTE:
The default daylight savings rule is 0, no daylight savings.
1. Type change daylight-savings-rules and press 
Enter
.