1. 
 An identification tag is permanently mounted on  
the cabinet.
2.  
Plug cabinet into a properly grounded receptacle 
ONLY, positioning the unit so the power supply  
cord is easily accessible in case of an emergency.
3. 
 If necessary, a proper receptacle or outlet  
configuration as required for this unit, must be 
installed by a licensed electrician in accordance with 
applicable, local electrical codes.
 
D A N G E R
To avoid electrical shock, this 
appliance MUST be adequately 
grounded in accordance with local 
electrical codes or, in the absence of 
local codes, with the current edition 
of the National Electrical Code ANSI/
NFPA No. 70.  In Canada, all electrical 
connections are to be made in 
accordance with CSA C22.1, Canadian 
Electrical Code Part 1 or local codes.
    D A N G E R
ELECTRICAL CONNECTIONS MUST 
BE MADE BY A QUALIFIED SERVICE 
TECHNICIAN IN ACCORDANCE WITH 
APPLICABLE ELECTRICAL CODES.
ELECTRICAL  • 1000-BQ2/128
 
voltage
 
phase
 
cycle
/
hz
 
amps
 kW 
cord
 & 
plug
 
included
 120 (
agcy
)  1
60
17.5  2.1 
NeMa
 5-20
p
 
 
 
 
 
 
 
20A- 125V 
plug
208-240 (
agcy
) 1
60
8.8  2.1 
NeMa
 6-15
p
 
 
208
1
60
7.7  1.6
15A - 250V
plug
 
240
1
60
8.9  2.1
 230 (
agcy
)  1
50/60
8.4  2.0 
cee
 7/7 
 
 
 
 
 
 
220-230V 
plug
ELECTRICAL  • 1000-BQ2/96
 
voltage
 
phase
 
cycle
/
hz
 
amps
   kW 
cord
 & 
plug
 
included
 120 
(
agcy
) 1 
60  12.5 1.5 
NeMa
 5-15
p
 
     
  15A- 
125V 
plug
208-240 (
agcy
) 1
60
7.0  1.6
NeMa
 6-15
p
 
 
at 208
1
60
5.9  1.2
15A - 250V
plug
 
at 240
1
60
6.8  1.6
 230 (
agcy
)  1
50/60
6.5  1.5
cee
 7/7 
 
 
 
 
 
 
220-230V 
plug
E L E C T R I C A L   C O N N E C T I O N 
I N S T A L L A T I O N
Wire diagrams are located inside the top of the unit . 
Hard wired models:
Hard wired models must be equipped with a 
country certified external allpole disconnection 
switch with sufficient contact separation.
If a power cord is used for the connection of the 
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
    D A N G E R
ENSURE POWER SOURCE 
MATCHES VOLTAGE STAMPED 
ON APPLIANCE NAMEPLATE.
For CE approved units:  To prevent an electrical 
shock hazard between the appliance and other 
appliances or metal parts in close vicinity, an 
equalization-bonding stud is provided. An 
equalization bonding lead must be connected to 
this stud and the other appliances / metal parts 
to provide sufficient protection against potential 
difference. The terminal is marked 
with the following symbol.
NOTE
:   
CE approved appliances must be 
connected to an electrical circuit that is 
protected by an external GFCI outlet.
ELECTRICAL • 1000-BQ2/192
 
voltage
 
phase
 
cycle
/
hz
 
amps
 kW 
cord
 & 
plug
 
included
 120 (
agcy
)  1
60  24.0  2.9
NeMa
 5-20
p
 
 
power
 
switch
 
in
 
low
 
position
   
16.0  1.9
 
20A- 125V 
plug
  
  
  
 
 
 
 
NeMa
 5-30
p
 
 
power
 
switch
 
in
 
high
 
position
   
25.0 
max
  3.0 
30A - 125V 
plug
208-240 (
agcy
) 1
60  13.5  3.3
NeMa
 6-15
p
 
 
at 208 
60   11.8  2.5 
15A - 250V 
plug
 
at 240
1
60  13.6  3.3
 230 
(
agcy
)  1 
50/60 13.0  3.0 
cee
 7/7 
 
 
 
 
 
 
220-230V 
plug