15
PRODUCT SPECIFICATIONS 
Items
Model
Defrost Heater(FRE)
Defrost Heater(REF)
DISPENSER Heater
FRENCH Heater
ICE Duct Heater
Water Tank Heater
Interlock with French Heater
-
Interlock with Defrost Heater (FRE)
-
Model
Temp.ON
Temp.OFF
Over load Relay
Rated Voltage
MOTOR-BLDC(FRE)
MOTOR BLDC(ICE ROOM)
MOTOR-BLDC(REF)
MOTOR-BLDC(CIRCUIT)
MOTOR-DAMPER(PANTRY)
Lamp(FRE)
Lamp(REF)
Conducting af F Defrost
Conducting at R Defrost
Door Switch
FRE
REF
REF(ICE ROOM)
Power cord
Earth Screw
Bimetal thermo For Preventing Overheating of Refrigerator Lamp
Specification
RF267 / RF26X
Electric Components
AC 115V, 240W
AC115V, 120W
AC115V, 2W
AC115V, 8W
AC115V, 4W
DC 12V, 2W
AC125V 10A / 140
℉(60℃) / On : 104℉(40℃)
4TM445PHBYY-82
257
℉± 9℉ (125℃±5℃)
156
℉± 16℉ (69℃±9℃)
AC 115V/ 60Hz
DC12V / DREP5020LC
DC12V / DREP5020LB
DC12V / DREP5020LC
DC 12V / DRCP5030LA
DC12V / NSBY001TA1
AC 120V / 60W(1EA)
AC 120V / 60W(2EA)
AC 125V 1.5A (1EA)
DC200V 1.5A / MS-406-SS-01(2EA)
125~250V /11A, EMB606
AC125V 15A
BSBN (BRASS SCREW)
AW-SEM Transform(RF267,2#3957D8  
2009.8.20 4:50 PM  