Instructions for the installer 
 
13 
3.  ADAPTATION TO DIFFERENT TYPES OF GAS 
 
 
 
Before performing any cleaning or maintenance work, detach the 
appliance from the electrical socket.
 
 
 
The cooker hob is set for natural gas G20 (2H) at a pressure of 1.0 
kPa. 
In the case of functioning with other types of gas the burner nozzles 
must be changed and the minimum flame adjusted on the gas taps. To 
change the nozzles, proceed as described below. 
 
3.1 Replacement of nozzles on the hob 
This operation requires no primary air regulation. 
1.
 
Extract the grids and remove all the caps and flame-spreader 
crowns; 
2.
 
unscrew the burner nozzles with a 7 mm socket wrench; 
3. 
replace the nozzles according to the type of gas to be used and the 
description in paragraph “3.2 Burner and nozzle characteristics 
table”.
 
Replace the burners in the correct position.