Листовка для Ingersoll-Rand 67384

Скачать
Страница из 2
CCN 15252406
SELF EVACUATING OIL DRAIN
OPERATOR’S MANUAL
67384
RELEASED:
8-25-05
REVISED:
         5- 25-10
(REV. 03)
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
OPERATING AND SAFETY PRECAUTIONS
WARNING
EXCESSIVE AIR PRESSURE. Can cause explosion resulting in
severe injury or death.
S
Do not exceed the maximum inlet air pressure as stated on the model plate.
WARNING
EXPLOSION HAZARD. Can cause serious injury or property dam-
age.
S
Do not use near open flame or heat source.
S
This product is not designed for working in explosive environments, including
those caused by fumes and dust, or near flammable materials.
WARNING
HAZARDOUS MATERIALS. Can cause personal injury or proper-
ty damage.
S
Do not use for volatile fuel and fluids.
S
Obtain Material Safety Data Sheets on all materials from the supplier for proper
handling instructions.
WARNING
HIGH PRESSURE AIR. Bypassing, modifying or removing the
safety / relief valve can cause serious injury or death. Do not bypass, modify or
remove the safety / relief valve. Do not direct air stream at body.
CAUTION
Be certain all operators of this equipment have been trained for
safe working practices, understand it’s limitations and wear safety goggles /
equipment when required.
S
Do not use for structural support.
S
Disconnect air supply when not in use.
S
Use only genuine IR replacement parts to assure longest service life.
GENERAL DESCRIPTION
Model 67384 is a waste oil container which stores up to 20 gallons (75.7 liters) in an ASME
certified steel tank and rapidly discharges using air pressure. The unit is equipped with a
safety relief valve which prevents over-pressurization and a 5” x 16” (12.7 cm x 40.64 cm)
drain funnel with a filtering screen and a telescoping tube. The tank has (2) rigid casters
and (2) swivel casters for easy maneuvering. It also includes a sight gauge and a dis-
charge cam lock coupler.
OPERATION
1. To raise the funnel: Grasp the upper portion of the (5) tube, loosen the (6) thumb screw
and raise the funnel and tube to the desired height. Tighten the (6) thumb screw and
release grasp on tube.
2. To lower the funnel: Grasp the upper portion of (5) tube, loosen the (6) thumb screw
and lower the funnel and tube to the desired position. Tighten (6) thumb screw and
release grasp on tube.
3. The reservoir includes a sight gauge. Do not overfill the reservoir.
4. To evacuate oil: Lower the (1) funnel. Always connect the discharge hose before con-
necting air supply. Connect the discharge hose to the (8) cam lock coupler on the (18)
tank. Be sure the (8) cam lock coupler is fully engaged. Open the (9) oil shut off valve.
Before connecting the air supply, be sure that the inlet air line pressure is regu-
lated at no more than 70 p.s.i. (PMAX).
Connect the air supply to the (10) air man-
ifold. Never leave theunit unattendedduring evacuation.Close the(12) airshut-off
valve immediately when the tank is empty. The discharge hose will begin to shake
when the (18) tank is empty. Disconnect the air supply to the (10) air manifold. Close
the (9) oil shut off valve. Slowly open the (12) air shut-off valve to depressurize the sys-
tem. System must be depressurized before returning to service. Disconnect the dis-
charge hose from the (8) cam lock coupler on the (18) tank. Periodically remove and
clean the (2) funnel screen as necessary.
5. (17) safety relief valve may discharge during evacuation.
DATA
Weight
115 lbs (52.2 kgs)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended Air Operating Pressure
20 - 70 p.s.i.g. (1.38 - 4.83 bar)
. . . . . .
Capacity
20 gallons (75.7 liters)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Height
(lowered)
52 in. (132.08 cm)
. . . . . .
. . . . . . . . . . . . . . . .
(fully extended)
73 in. (185.42 cm)
. . . . . . . . . . .
Tank Diameter
16 in. (40.64 cm)
. . . . . . . . . . . . . . . . . . . . . . . . .
1
5
9
6
20
Figure 1
7
3
30
8
19
10
18
FLOAT VALVE SERVICE PROCEDURES
1. Depressurize system before and during servicing.
2. Wear appropriate safety equipment during servicing.
3. Remove (1) funnel from (5) tube.
4. Remove (6) thumbscrew from (7) collar.
5. Unbolt (30) handle and remove from the (18) tank.
6. Loosen the (7) collar and remove the (5) tube from the (18) tank.
7. To loosen the (7) collar, it may require the use of an industrial heat gun to soften the
pipe thread sealant on the (7) collar thread.
a. WARNING -- Do not use an open flame.
b. WARNING -- Be sure the tank vents are open during service.
c. WARNING -- Keep heat away from product labels.
8. Use a large spanner wrench or 12” pipe wrench to remove the (7) collar.
9. Secure tank when removing the collar.
10. Remove the (27) roll pin and the (25) ball from the (26) seat.
11. Remove the (26) seat by unscrewing the seat from the (5) tube.
12. Remove debris and particulates from the (27) roll pin, (25) ball and (26) seat using mild
detergent and water.
a. WARNING -- Do not use solvent, as this may damage the ball.
13. Before reassembly, apply PTFE tape to the (26) seat threads.
14. Assemble in reverse order. Apply Loctite PST or equivalent pipe thread sealant to the
(7) collar threads prior to assembly. Tighten securely.
15. Test all joints for air leakage prior to putting drain back into service.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
 
(800) 495-0276   FAX(800) 892-6276
© 2010 
www.ingersollrandproducts.com