3. INSTALLATION 
3.5  Installation 
 
 
I - 17 
3.5  Installation 
 
Each unit is installed in the sealed structure cabinet as a principle. When installing into the cabinet, refer 
to the following drawings to consider the control unit's heat radiation and wiring, and secure enough 
space for ventilation. 
(1)  Install each unit vertically so that the front is visible. 
(2)  Refer to the following drawings to consider the control unit's heat radiation and wiring, and secure 
enough space for ventilation. 
 
(Top)
(Bottom)
Servo drive unit
Spindle drive unit Power supply unit
 
Control unit 
50mm or more 
(heat dissipation, 
wiring allowance) 
*10mm or more
when there is a 
unit on the left 
100mm or more   
(heat dissipation,   
wiring allowance)
 
10mm or more 
(heat dissipation, 
wiring allowance)
MITSUBISHI 
MELDAS 
C64 
50mm or more 
(heat radiation 
allowance) 
 
 
(Note)  The right side of the control unit will temporarily expand by approx. 2mm when the 
expansion card is inserted and removed. 
 
It will not be possible to insert or remove the expansion card if there is no space between 
the control unit and adjacent unit. Always provide sufficient space. 
 CAUTION 
 
 Install the control unit and communication terminal on noncombustible material.  
Installation directly on or near combustible material may lead to fires. 
 
  Always observe the installation direction. 
 
  Do not install or operate a control unit or communication terminal that is damaged or that 
has missing parts. 
 
  The control unit and communication terminal are precision devices so do not drop or 
apply strong impacts on them.