4. CONTROL UNIT CONNECTIONS 
4.9    Connecting the Remote I/O Unit 
 
 
I - 32 
  4.9    Connecting the Remote I/O Unit 
 
The RIO-M connector is used to connect the remote I/O unit. Connect the R211 cable from the RIO-M 
connector on the control unit to RIO1 on the remote I/O unit. 
When connecting multiple remote I/O units, connect the R211 cable from the RIO2 connector to the 
RIO1 connector on the next remote I/O unit. 
Connect the terminator (R-TM) to RIO2 connector on the final remote I/O unit. Use the accessories for 
the connectors and contacts when manufacturing the R211 cable. If the accessories are insufficient, 
prepare the CN221 one end connector set (optional, with one end). 
(Refer to the CABLE MANUFACTURING DRAWINGS for details.) 
 
 
Back 
Front 
RIO-M 
R211 cable 
RIO-M
Bottom 
Back 
RIO1/RIO
2
FCUA-DX
†††
Connect the terminator (R-TM) to RI02 
connector on the final remote I/O unit. 
Front 
RIO-M
RIO-M/S
R211 cable 
RIO2
RIO1
RIO2
Recommended adaptive connector 
(Enclosed with FCUA-DX
†††) 
Terminator (R-TM)
Front 
Back 
Bottom
RIO1
RIO2
DCIN
Connector  : 1-178288-3 2pcs. 
Contact 
: 1-175218-2(gold plate) 6 pcs.   
(Tyco Electronics AMP) 
RIO-
M
RIO-
M
/
Bottom
RIO-M 
RIO-M/S
1  TxRx
2  TxRx*
3  LG
 
Terminator
R-TM
 
(Tyco Electronics AMP) 
R211 cable 
X
R211 cable 
X
R211 cable 
RIO1 
1   TxRx
2  TxRx*
3  LG
 
 
 CAUTION 
 
  Incorrect connections could cause device damage, so always connect the cables to the 
designated connectors. 
 
  Do not connect or disconnect the connection cable between each unit while the power 
is ON. 
 
  Separate the signal wire from the drive line/power line when wiring.