CONNECTION OF REMOTE I/O UNIT 
6.1  Outline of Remote I/O Unit  
 
 
I - 
55
 
6. CONNECTION OF REMOTE I/O UNIT 
 
This chapter describes the connection between remote I/O unit and machine control signals. 
 
 
6.1  Outline of Remote I/O Unit 
 
The following ten types of remote I/O units (FCUA-DX 
†††) are available, depending on the type of 
input/output signal and No.of contacts. Use serial link connections (MC link B) to connect the unit with 
the control unit or the communication terminal. 
When the remote I/O unit is connected with serial links, multiple units can be used as long as the total 
No. of occupied stations (channels) is within 8 stations. (Refer to Section 6.3 "Setting the Station No. 
When Using Multiple Remote I/O Units" for details.) 
 
Unit name 
Machine control signals that can be handled 
No. of occupied 
serial link stations
FCUA-DX100 
Digital input signal (DI) 
:  32 points (insulation) sink/source type 
Digital output signal (DO)  :  32 points (non-insulation) sink type 
FCUA-DX101 
Digital input signal (DI) 
:  32 points (insulation) sink/source type 
Digital output signal (DO)  :  32 points (non-insulation) source type 
FCUA-DX110 
Digital input signal (DI) 
:  64 points (insulation) sink/source type 
Digital output signal (DO)  :  48 points (non-insulation) sink type 
FCUA-DX111 
Digital input signal (DI) 
:  64 points (insulation) sink/source type 
Digital output signal (DO)  :  48 points (non-insulation) source type 
FCUA-DX120 
Digital input signal (DI) 
:  64 points (insulation) sink/source type 
Digital output signal (DO)  :  48 points (non-insulation) sink type 
Analog output (AO) 
:  1 point 
FCUA-DX121 
Digital input signal (DI) 
:  64 points (insulation) sink/source type 
Digital output signal (DO)  :  48 points (non-insulation) source type 
Analog output (AO) 
:  1 point 
FCUA-DX130 
Digital input signal (DI) 
:  32 points (insulation) sink/source type 
Digital output signal (DO)  :  32 points (non-insulation) sink type 
Handle input 
:  2 points 
FCUA-DX131 
Digital input signal (DI) 
:  32 points (insulation) sink/source type 
Digital output signal (DO)  :  32 points (non-insulation) source type 
Handle input 
:  2 points 
FCUA-DX140 
Digital input signal (DI) 
:  32 points (insulation) sink/source type 
Digital output signal (DO)  :  32 points (non-insulation) sink type 
Analog input (AI) 
:  4 points 
Analog output (AO) 
:  1 point 
FCUA-DX141 
Digital input signal (DI) 
:  32 points (insulation) sink/source type 
Digital output signal (DO)  :  32 points (non-insulation) source type 
Analog input (AI) 
:  4 points 
Analog output (AO) 
:  1 point