6.
 
CONNECTION OF REMOTE I/O UNIT 
6.14  Connection of FCUA-DX14 
† Unit and Analog Input/Output Signal 
 
 
-
 72 
6.14  Connection of FCUA-DX14 
† Unit and Analog Input/Output Signal 
 
For the analog input/output signal, the R031 cable is connected to AI0. Up to four input points and one 
output point of the analog input/output signal can be connected. When manufacturing the R031 cable, 
use the CS000 connector set (optional, with both ends).  
 
 
AIO
FCUA-DX14† 
1
10
11
 
20
 
Pin No.
R031 cable
 
 
 
     
Input/output circuit 
 
DAC
220
Ω
R
R
150
Ω
ADC
A10
 
A0
 
FCUA-DX14† 
GND
 
Input 
Output 
Connector pin No.
GND
 
GND
 
GND
 
A11
 
A12
 
A13
 
13 
12 
150
Ω
150
Ω
150
Ω
11 
15 
 
 
 
 
 CAUTION
 
 
  Incorrect connections could damage the device, so always connect the cable to the 
designated connector. 
 
  Do not connect or disconnect the connection cables between each unit while the power 
is ON.