Adjust Gas Pressure to Kettle Burners 
10
313879B
Adjust Gas Pressure to Kettle Burners
1.
Shut off kettle gas safety valve (CC).
2.
Turn kettle temperature control knob (AA) to 0 
(“OFF”).
3.
Remove kettle gas safety valve 1/8-27 NPT pipe 
plug.
4.
Screw 0 to 30 in. w.c. (0 to 7.47 cb) calibrated gas 
pressure gauge or manometer into kettle gas safety 
valve outlet.
5.
Ignite kettle gas pilot burner. 
6.
Turn kettle gas safety knob (CC) to ON.
7.
Turn kettle temperature control to 250° F (121° C).
8.
Record gas pressure at kettle gas safety valve out-
let. Gas pressure should read 11 in. w.c. (2.74 cb).
9.
Remove adjusting screw cap.
10. Turn adjusting screw (148) clockwise to increase 
gas pressure (counterclockwise to decrease gas 
pressure).
11. Install adjusting screw cap.
12. Turn kettle temperature control knob (AA) to 0 
(“OFF”).
13. Shut off kettle gas safety valve (CC).
14. Remove gas pressure measuring device.
15. Add LP-gas pipe sealant to 1/8-27 NPT pipe plug 
(156) and install in kettle gas safety valve.
ti14518a