Руководство Пользователя для Hoshizaki rf28a
A. Startup
WARNING
The unit comes with the drain tank cover installed on the rear of the machine.
Due to heat generated in the drain tank area, this cover must be in place when
the unit is operating.
Due to heat generated in the drain tank area, this cover must be in place when
the unit is operating.
1) Plug in the unit. The evaporator fan starts.
2) The compressor and condenser fan motor will start in 3 minutes.
2) The compressor and condenser fan motor will start in 3 minutes.
B. Cabinet Temperature Setting
The cabinet temperature is factory-adjusted to 37°F (3°C) for refrigerator models and
0°F (-18°C) for freezer models. If necessary, readjust the temperature as follows:
0°F (-18°C) for freezer models. If necessary, readjust the temperature as follows:
1) Press the
button to display the current setpoint temperature.
2) To change the setpoint, press and hold the
button while pressing the
up or
down button to raise or lower the setpoint. The cabinet temperature is adjustable
between 21°F and 54°F (-6°C and +12°C) for refrigerator models and between -13°F
and 19°F (-25°C and -7°C) for freezer models.
and 19°F (-25°C and -7°C) for freezer models.
3) The new setpoint will be saved automatically 10 seconds after releasing the buttons.
Note: The displayed cabinet temperature is adjusted to be almost equal to the
temperature at the center of the cabinet without foods. But it can be different from
the actual temperature depending on arrangement of stored foods, frequency of
door opening or location of measuring points.
the actual temperature depending on arrangement of stored foods, frequency of
door opening or location of measuring points.
Fig. 5
Temperature
Display Window
Manual Defrost Button
Setting Buttons
Service Button
9